Operation; Adjusting The Output Level; Specifications - Monacor VCA-202 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für VCA-202:
Inhaltsverzeichnis
Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
If there is no external control voltage, the output
voltage (10 V) provided at the screw terminals* (7)
can be used. For this purpose it is recommended to
use potentiometers with a value of 10 kΩ and a
linear characteristic (e. g. MONACOR VCA-202RN).
Connect the potentiometers according to fig. 3.
If a stereo source is connected, the control
inputs (6) of both channels have to be connected in
parallel according to fig. 4.
4) Finally connect the plug of the mains cable (3) to a
mains socket (230 V~/50 Hz).

5 Operation

1) Prior to switching on, the control voltages should be
set to 0 V to prevent loud switching noise.
2) Switch on the unit with the POWER switch (1). The
red POWER LED (2) lights up.
3) Switch on the connected units, always switch on the
power amplifier for the speakers last.
4) When switching off the system, always switch off
the power amplifier first.

5.1 Adjusting the output level

The output level is adjusted with a DC voltage. The con-
trol range is between 0 and 10 V, at 0 V there is no out-
put level. There is a linear rise of the output level ac cor-
d ing to the control voltage. The maximum amplification
is 1 (0 dB) and appears at a control voltage of 10 V.

6 Specifications

Inputs
2 × LINE, mono: . . . . . . . 1 V/30 kΩ, bal.
2 × control input: . . . . . . . 0 – 10 V
Outputs
2 × LINE, mono: . . . . . . . 1 V/600 Ω, bal.
1 × control voltage: . . . . . 10 V
Frequency range: . . . . . . . . 20 – 20 000 Hz
THD: . . . . . . . . . . . . . . . . . . 0.1 %
S/N ratio: . . . . . . . . . . . . . . 70 dB, unweighted
Power supply: . . . . . . . . . . . 230 V~/50 Hz/10 VA
Ambient temperature: . . . . . 0 – 40 °C
Dimensions (W × H × D): . . 482 × 48 × 105 mm,
Weight: . . . . . . . . . . . . . . . . 1.5 kg
Subject to technical modification.
All rights reserved by MONACOR
be reproduced in any form or by any means for any commercial use.
/100 kΩ
/5 mA max.
1 rack space
INTERNATIONAL GmbH & Co. KG. No part of this instruction manual may
®
GB
7
Inhaltsverzeichnis
loading

Inhaltsverzeichnis