Fixture - Dometic 7103 Installation, Gebrauch, Wartung

Kochfelder und kombinationen
Inhaltsverzeichnis
Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 32
PI7203 - PI7223 - PI7703 - PI7723 - PI7803
PI7823 - PI8003 - PI8023 - PI8043 - PI8063
PI8403 - PI8423 - PI8443 - PI8463
MO9303 - MO9323 - MO9423 - MO9503
MO9523 - PI7903 - PI7923 - PI8723
MO7464 - MO7464SC - MO7464SCSP - MO7464SP
The gas supply pipe connected to the appliance must be a rigid metal pipe with sealed fittings. It is possible to fit a
flexible hose, however, in this case the following conditions must be respected:
a) The hose can be accessed easily for inspection;
b) The hose must be protected against coming into contact with parts which heat up (for example parts
underneath the burners);
c) The hose must be protected against being damaged (twisting, pulling, trapping,....);
d) The hose must be protected against being trapped by moving parts (e.g. drawers);
e) The hose must not have a length over 1.5 m;
f) The hose must be replaced before its expiry date;
For models PI8621A, PI8621S, PI8621R seal the appliance gas pipe utilising the sealed tube with pre-mounted
gas fitting provided. Once the appliance has been connected to the gas supply check for gas leaks utilising a noncorrosive
fluid. Do not use a water and soap solution. NEVER USE A FLAME TO TEST FOR GAS LEAKS.
Models PI8621A, PI8621S and PI8621R are modular. It is possible to connect from 1 to 5 appliances in series.
Disconnect and remove the sealed tube mounted to the gas pipe on the installed appliance and connect it to the
gas pipe on the appliance to install. Connect the appliances together by connecting the gas pipes in series utilising
the fitting.
CONNECTING TO ELECTRICITY SUPPLY
LOW VOLTAGE 12 V
This chapter refers only to models with the wording 12 V
appliance.
To connect the appliance, use a double cable and connect it to the terminal board identified with "+12 V
found on the back side of the appliance.
The red terminal is the positive pole, while the black terminal is the negative pole.

FIXTURE

THIS APPLIANCE MUST BE FITTED AND SECURED TO THE CABINET UTILISING THE FIXTURE SCREWS AS
ILLUSTRATED IN FIG. 3 - PG 142.
LIBR34RB_1.indd 15
Downloaded from
www.Manualslib.com
HBH1303ILG - HBH1303IRG
PI7903T - PI7923T
PI8004 - PI8024
WHEN INSTALLING AND CONNECTING THE APPLIANCE TO THE GAS SUPPLY,
ENSURE THAT THE GAS SUPPLY HOSE IS NOT TWISTED, STRETCHED OR
SUBJECTED TO ANY FORM OF STRAIN WHICH COULD CREATE A HAZARD.
THIS APPLIANCE MUST BE CONNECTED TO A 12 V
MM2 CABLE IS USED FOR THE CONNECTION, ITS LENGTH MUST NOT EXCEED 2
METERS.
WHEN WIRING THE APPLIANCE RESPECT CORRECT POLARITY!
NEVER CONNECT THE APPLIANCE TO THE MAIN VOLTAGE (230 V~); THIS WOULD
RESULT IN THE ULTIMATE DESTRUCTION OF THE PARTS AND A HAZARD TO THE
USER.
manuals search engine
4,8 - 350
4,6 - 335
4,9 - 356
5,0 - 364
5,6 - 408
6,8 - 495
n the appliance specifications label affixed to the
POWER PACK. IF A 2 X 0,5
9,6
9,2
9,8
10,0
11,2
13,6
–",
17/04/18 11:35
Inhaltsverzeichnis
loading

Inhaltsverzeichnis