Application
• Fitting for use with function unit 36 065.
• The maximum permissible distance between the operating
panel and functional unit 36 065 is 3m.
Technical Data
• Flow rate at 3 bar flow pressure:
• Automatic safety shut-off (factory setting):
• Radio frequency:
• Transmitter power:
• Operating panel battery: 3 V lithium battery (type CR 2032)
• Type of protection:
Approval and conformity
This product conforms to the requirements of the
relevant EU guidelines.
The conformity declarations can be obtained from the following
address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
Installation
Install spout, see fold-out page II, Figs. [1] to [4].
1. Screw in connection nipple (A) loosely, see fold-out page II,
Fig. [1].
2. Fit escutcheon (B) and fasten together with connection
nipple (A), see Figs. [2] and [3].
3. Install spout (C), see Fig. [4].
Grease O-rings with the special grease supplied prior to
installation.
Install operating panel, see Figs. [5] and [6].
Insert batteries with correct polarity.
Open isolating valve and check connections for
watertightness.
approx. 20 l/min
2.4332 GHz
< 0.05 mW
- Operating panel

Operation

Synchronise operating panel with functional unit
Disconnect plug-in connector, battery unit and plug power
supply of functional unit 36 065 and reconnect again after 10 s.
The functional unit is now in receive mode for 60 s.
Using the operating panel
60 s
Start/Stop button
Starts and stops the fitting at a preset temperature
(factory setting 38 °C) and full flow rate.
IP 57
Pause button
Interrupts the flow of water. The flow is resumed by
pressing the button again.
The fitting switches off automatically after a preset
time (factory setting 60 s).
Temperature
Increases (red arrow, left) or decreases (blue arrow,
right) the water temperature.
Volume
Increases
four stages.
Flush piping system prior and after installation of fitting
thoroughly (Consider EN 806)!
Define start temperature
Press and hold the button for 10 seconds
=> 3 water pulses
Adjust until optimum temperature is reached
=> 3 water pulses

Maintenance

Battery, see Fig. [5].
The battery must be replaced 10 years after commissioning
the fitting, at the latest.
Install in reverse order.
Replacement parts
See fold-out page I (* = special accessories).
Disposal note
Dispose of batteries in accordance with national
regulations.