Commissioning

7.1

Alignment

7.2

Check the application conditions

8020346.1DS6/2021-11-24 | SICK
Subject to change without notice
Table 11: Test
WTB16P: Align the sensor with the object. Select the position so that the red emitted
light beam hits the center of the object. It is important to ensure that the optical
opening (front screen) of the sensor is completely clear
WTB16I: Align the sensor with the object. Select the position so that the infrared light
(not visible) hits the center of the object. The correct alignment can only be detected
via the LED indicators.
see figure
ensure that the optical opening (front screen) of the sensor is completely clear.
Table: Alignment
Figure 13: Alignment 1
WTB16 are photoelectric proximity sensors with background suppression. Depending
on the remission of the object to be detected, and perhaps the background behind it,
a minimum distance (y) between the set sensing range (x) and the background is to be
maintained.
Test → M
+ (L+)
Test
– (M)
+ (L+)
Test
– (M)
[see figure 13figure
13,
figure
14,
table
2,
table 9
Figure 14: Alignment 2
O P E R A T I N G I N S T R U C T I O N S | WTB16
7
COMMISSIONING
Test → L+
+ (L+)
Test
– (M)
+ (L+)
Test
– (M)
14].
and
table
4. You must