Important
The flatness of the mounting plate surface to which the load cell is attached
must be better than 0.02 mm.
4.3

Connection for pressure compensation

The load cell housing is fitted with a connection for pressure compensation.
Important
Changes in air pressure will also affect the measurement result, if you do not
connect the valve coupling plug (the load cell is then sealed).
Connection in a dry environment
Fit the valve coupling plug, to ensure pressure compensation.
Connection in a damp environment
In a damp environment, e.g. if the load cell can get wet when using liquid
cleaning agents for cleaning, you must take suitable precautions to ensure that
moisture cannot get into the load cell.
Connect the valve coupling plug with a suitable hose that leads into a dry area.
If you use a number of load cells, you can interconnect them in a pressure
compensation loop.