2. Functional Description

2.1 General Points
The SATAjet 3000 K RP/HVLP paint spray gun is designed for corrosives, glazes, spraying paints and
laquers as well as other media in connection with paint pressure pots or pumps up to spray viscosities
which are no more measurable with the DIN-4 cup (Nozzle size depends on spray viscosity). Materials
that are abrasive, acidic or contain benzine must not be used. The compressed air supply required
for spraying is fed to the air connection screwed into the gun grip. Squeezing the trigger as far as the
first pressure point opens the air valve (pre-air control). When the trigger is squeezed further, the paint
needle is pulled out of the paint nozzle. The spraying medium flows under pressure out of the paint
nozzle and is simultaneously atomized by the compressed air that flows the air nozzle.
The digital pressure measuring device „SATA adam" is used for exactly indicating and adjusting the
spray pressure with almost all SATA paint spray guns. This allows to adjust an exactly reproduceable
spray pressure for the paint spray guns at any time, even with varying operation conditions.
2.2 Digital Pressure Measurement (add-on solution)
From 0.2 bar (3 psi) on, the digital pressure measuring device integrated in the „SATA adam" indicates
the gun inlet pressure with an indication precision of ± 0.05 bar (1 psi). If unpressurized, the pressure
measurement is put into „sleep" mode to prolong battery life time. The pressure measuring device
is hermetically sealed against external influence (max. temperature 60° C). The maximum indication
value is 99 psi or 9.9 bars.
2.3 ATEX, FM Global (Explosion hazard safety)
The digital pressure measurement device „adam" has been submitted to a prototype test and was
developed, constructed and manufactured in accordance with the EC Directive 94/9 EG.
It was categorized according to
and may be used in the explosion hazard zones 0, 1 and 2 with a temperature of up to 60° C. In
case of damage to the pressure measuring device, indication, glass cover etc. put gun out of order
immediately. The pressure measurement device may exclusively be repaired in the SATA company.
Any intrusion into the pressure measuring chamber by removing the front plate is dangerous,
will lead to the expiry of the explosion hazard safety certificate as well as the warranty, and
destroys the pressure measurement device.
3. Construction
1
Nozzle set (air cap visible only)
2
Self tensioning needle packing (not visible)
3
Trigger
4
Self tensioning air piston packing
(not visible)
5
Stepless regulation for round and flat spray
6
ColorCodeSystem
III.2
II 1G EEx ia IIC T4
FM Global IS CL I, ZN 0, AEx ia IIC T4
IS CL I, DIV 1, GP A, B,C&D, T4
7
Air connection G ¼ outside
8
Air piston (not visible)
9
Fixing screw
10 Air micrometer
11 Fluid adjustment
12 SATA adam