Program settings

Program setting of ECS 40/ECS 41 can be performed
via the start guide or directly in the menu system.

Start guide

The start guide appears upon first start-up after heat
pump/indoor module installation, but is also found in
menu 5.7.

Menu system

If you do not make all settings via the start guide or
need to change any of the settings, this can be done
in the menu system.
Menu 5.2 - system settings
Activating/deactivating of accessories.
Select: "climate system 2" for climate system 2, "climate
system 3" for climate system 3, and "climate system 4"
for climate system 4.
1) Applies to NIBE F1145, F1155, F1245, F1255, F370, F470, F730
and F750.
Menu 5.2.4 - accessories
Activating/deactivating of accessories.
Select: "climate system 2" for climate system 2, "climate
system 3" for climate system 3, and "climate system 4"
for climate system 4.
2) Applies to NIBE F1345, SMO40, VVM 310, VVM 320, VVM 325
and VVM 500.
Menu 5.1.2 - max flow line temperature
Setting the maximum flow temperature for each cli-
mate system.
Menu 5.3.3 - extra climate system
Mixing valve settings for extra installed climate system.
Menu 1.1 - temperature
Setting the indoor temperature.
Menu 1.9.1 - heating curve
Setting the heat curve.
Menu 1.9.2 - external adjustment
Setting external adjustment.
Menu 1.9.3 - min. flow line temp.
Setting the minimum flow temperature for each climate
system.
Menu 1.9.4 - room sensor settings
Activating and setting the room temperature sensor.
32
1)
2)
Menu 5.6 - forced control
Forced control of the different components in the heat
pump/indoor module as well as in the different ac-
cessories that may be connected. EP21 is climate system
2, EP22 is climate system 3, EP23 is climate system 4.
EP2#-AA5-K1: No function.
EP2#-AA5-K2: Signal (close) to mixing valve (QN25).
EP2#-AA5-K3: Signal (open) to mixing valve (QN25).
EP2#-AA5-K4: Activating the circulation pump (GP20).
Caution
Also see the Installer manual for relevant heat
pump/indoor module/control module.

Technical specifications

ECS
Control voltage
cw
value
s
Connection valve (Ø mm)
40
41
230 V
4,0
6,3
22