INSTALLATION GUIDE
1
MOUNTING & WIRING
2
RADAR OPENING IMPULSE FIELD
2.2 m
from 15° to 45°, default 30 °
2.2 m
4 m x 2 m (wide)
**
field size: 9
immunity: 2
from -15° to 15°, default 0°
field size: 9
immunity: 2
2 m x 2.5 m (narrow)
The size of the detection field varies according to the mounting height of the sensor.
GREEN
12-24 V
BROWN
AC-DC
*
YELLOW
WHITE
PINK
*
GREY
RED
BLUE
* Output status when sensor is operational
** For compliance with EN 16005 and DIN 18650,
connection to door controller test output is required.
2.2 m
2.2 m
POWER SUPPLY
OPENING INPUT
SAFETY INPUT
TEST
OUTPUT
field size: 9
immunity: 2
field size: 9
immunity: 2