5.1.3

Avoiding damage to cables

In order to avoid damage to the motor's power cable whilst being
lowered into the well this should be fastened to the pressure line
using cable clamps. Fastening them together at two meter
intervals is recommended.
Pos: 56 /Technische Dokumentation/Betriebsanleitung/Installation/Rohrleitungen/Rohrleitungen @ 0\mod_1427882317137_370.docx @ 27152 @ 2 @ 1
5.2

Pipes

Pos: 57 /Technische Dokumentation/Betriebsanleitung/Installation/Rohrleitungen/Rohrleitungen dimensionieren - ZIS 40 @ 3\mod_1444975835990_370.docx @ 48805 @ 3 @ 1
5.2.1

Pipework dimensioning

Permanent installation:
We recommend using pipes made from metal or plastic with
G 1 ¼ connections. These will be fastened to the pump using
clamps.
Temporary installation:
We recommend using G 1 ¼ hoses with the same size
connection pieces.
Pos: 58 /Technische Dokumentation/Betriebsanleitung/Installation/Rohrleitungen/Rohrleitungen verlegen - ZIS 40 @ 3\mod_1444976018278_370.docx @ 48820 @ 3 @ 1
5.2.2

Laying pipes

Keep the pressure line as straight as possible.
Avoid sudden changes to the cross-section and direction.
In cases where the geodetic head is significant, the pipe
dimensioning must be adjusted in order to guarantee an
almost loss-free flow.
NOTE
A non-return valve must be installed in the outlet tube min 4 m
away from the outlet opening!
When using plastic hoses, these must withstand the pressure
of the pump. Kinks in the pipe should be avoided in order to
achieve normal function of the pump and the required water
quantity.
Pos: 59 /Technische Dokumentation/Betriebsanleitung/Installation/Aufstellung/ZIS 40/Montage/Demontage @ 3\mod_1444976154234_370.docx @ 48837 @ 2 @ 1
5.3

Assembly/disassembly

The pump is delivered completely assembled. Should the pump
need to be disassembled due to damage or otherwise, this must
be carried out by an authorized customer service representative.