1.1. INFORMATION ABOUT THIS INSTRUCTIONS MANUAL
This instruction is only intended for use with manifold product type:
•
MPLH0MS, MSLHEMS – Single stage manifold with manual change over for two cylinders
•
MSLH0MS, MSLHEMS – Single stage manifold with manual change over for two cylinders
Manifolds of this type are suitable to take gas out of gas cylinder or bundle and reduce the pressure. These
manifolds were installed as permanently wall assembly and are connected to gas cylinder or bundle with
coil or hose.
These instructions enable you to operate the system safely and efficiently. These instructions form an integral
part of the system and must always be kept with the system and within easy reach of staff at all times.
Prior to commencing any work, the staff must read these instructions carefully and understand the contents.
Observance of all the safety information and instructions for operation that are contained in these instructions
is essential to ensure work safety.
Local accident prevention regulations and general safety regulations governing the use of the system must
also be observed.
Illustrations in these instructions serve to ensure a basic understanding of the system and may differ from
the actual version.
1.2. INFORMATION ABOUT THIS MANIFOLD
Manifolds of this type are only suitable for gases defined as standard gas. The maximum working pressure
for these manifolds is 300 bar.
Single stage manifolds consists of valves and a pressure regulator with metal diaphragm, created and
approved as ISO7291/ISO10297 including oxygen shock test.
Product Line
H0 - High Pressure Regulator
with
FKM
LV - Low Pressure Regulator
with
FKM
Relief Valve Seat
Seat
DruvaPUR Line
(purity 6.0 | brass chrome plated)
•
Suitable Gases
(including their mixtures)
•
High Purity
•
Inert
•
Flammable
•
Oxidizing
•
Use for O2
•
Not Suitable Gases
(including their mixtures)
•
Corrosive
•
Toxic
•
Not for CO2, N20
•
Suitable Gases
(including their mixtures)
•
High Purity
•
Inert
•
Flammable
•
Oxidizing
•
Use for O2
•
Not Suitable Gases
(including their mixtures)
•
Corrosive
•
Toxic
•
Not for CO2, N20
4/64
DruvaPUR Line
(purity 6.0 | stainless steel)
•
Suitable Gases
(including their mixtures)
•
High Purity
•
Inert
•
Flammable
•
Oxidizing
•
Corrosive (in doubt ask)
•
Toxic (in doubt ask)
•
Not Suitable Gases
(including their mixtures)
•
Not for O2
•
Not for CO2, N20
•
Not for NH3, SO2, H2S
•
Suitable Gases
(including their mixtures)
•
High Purity
•
Inert
•
Flammable
•
Oxidizing
•
Corrosive (in doubt ask)
•
Toxic (in doubt ask)
•
Not Suitable Gases
(including their mixtures)
•
Not for O2
•
Not for CO2, N20
•
Not for NH3, SO2, H2S