Rupes ER123TES Bedienungs- Und Wartungsanleitung Seite 7

Exzenterschleifer
Inhaltsverzeichnis
pad, making sure that the holes cut in the paper disc coincide
with those in the pad.
DUST EXTRACTION
ATTENTION Hazardous dust can be produced during
sanding operations: Always connect an adequate
extraction device
In case of work producing dust, wear a mask
INTEGRATED EXTRACTION
- To guarantee optimal extraction of the powder empty the
conical filter (8) in time, accurately cleaning the filter holder
(8a) and regularly cleaning the cartridge (8b);
- During works on the vertical surfaces, position the machine
so the conical filter is turned downwards.
- Conical filter assembly: position the conical filter (8) on the
extractor tube coupling (4). Push the conical filter until it stops.
- Conical filter filling testing: the filling status of the conical filter
is easily controlled using the transparent filter holder (8.a).
- Conical filter cleaning: to empty the conical filter, remove
it from the extractor tube coupling working in the opposite
direction to assembly;
- Release the cartridge (8.b) and release it from the filter holder;
- Empty the filter holder;
- Clean the cartridge plates with a soft brush.
EXTERNAL EXTRACTION
- During vertical surface works position the machine in such a
way the extractor tube is turned downwards.
- Assembly: insert an extractor tube on the coupling for the
extractor tube (4);
- Connect the extractor tube to an adequate vacuum system
(not supplied).
ALLOWED ACCESSORIES
ER123TES - ER125TES
Ø 125 mm velcro abrasive paper discs with dust extraction holes.
ER153TES - ER155TES
Ø 150 mm velcro abrasive paper discs with dust extraction holes.
NOISE EMISSION VALUES
Detected noise emission values comply with the following
directives:
EN 60745
SOUND PRESSURE LEVEL
SOUND POWER LEVEL
UNCERTAINTY
SOUND PRESSURE LEVEL
SOUND POWER LEVEL
UNCERTAINTY
Use ear protection!
VIBRATION EMESSION VALUES
Detected vibration emission values comply with the standard
EN 60745
3 AXIS VIBRATION LEVEL
UNCERTAINTY
3 AXIS VIBRATION LEVEL
UNCERTAINTY
ER123TES
ER125TES
ddB(A)
74
74
dB(A)
85
85
K
3
ER153TES
ER155TES
ddB(A)
75
75
dB(A)
86
86
K
3
ER123TES
ER125TES
m/s
1.85
2.0
2
K
0.5
0.5
ER153TES
ER155TES
m/s
2.0
2.15
2
K
0.5
0.5
Displayed emission values are comparative and are to be
employed for a provisional assessment of the operator's risk
exposure during the work period. Appropriate evaluation of
work period must also include tool's idle and stop periods.
These emission values represent the tool's main applications.
If the tool is used for other applications, with other accessories,
or if it does not undergo regular maintenance, emission values
can significantly increase during operations.
Danger! The indicate measurements refer to new power
tools. Daily usa causes the noise and vibration values
to change.
MAINTENANCE
All maintenance operations are carried out with the power
supply disconnected.
At the end of each work session, or when required, remove any
dust from the body of the tool using a jet of compressed air,
paying particular attention to the motor ventilation slots.
No other maintenance operations must be undertaken by
the user.
Maintenance and cleaning of the inner parts, like brushes, ball
bearings, gears etc. or others, must be carried out only by an
authorized customer-service workshop.
DISPOSAL (WEEE Directive)
For EC countries only: According to the European
Directive on Waste from electrical and electronic
equipment and its implementation in conformity with
national standards, exhausted electrical equipment must be
collected separately, in order to be recycled in an environmentally
friendly way. The product, when it reaches the end of its life,
must not be dispersed in the environment or thrown away as
household waste. It must be disposed at authorized recycling
centres (contact your local authorities to know where to dispose
of the product according to the law). The correct disposal of the
product contributes to the health and preservation of the
environment. Illegal disposal of the product will entail penalties
against the offenders.
CONFORMITY DECLARATION
We declare on our responsibility that the represented tool is in
conformity with the directives:
2006/42/CE; 2011/65/CE; 2014/30/CE; 2014/35/CE
The tests have been carried out in accordance with following
Standards:
EN 60745-1: 2009 + A11: 2010
EN 60745-2-4:2009+ A11:2011.
3
EN 55014-1: 2006 + A1: 2009 + A2: 2011
EN 55014-2: 1997 + A1: 2001 + A2: 2008
EN 61000-3-2: 2006 + A1: 2009 + A2: 2009
EN 61000-3-3: 2008
3
EN 50581: 2012
Technical file at:
RUPES SpA
Via Marconi, 3A
20080 - Vermezzo (MI) - Italy
Vermezzo (MI), 21/09/2016
S.p.A
THE PRESIDENT
G. Valentini