To Be Filled In By The Installation Engineer When The Heat Pump Is Installed - Nibe HPAC 28 Montage- Und Bedienungsanweisung

Vorschau ausblenden Andere Handbücher für HPAC 28:
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

GB General
In order to get the ultimate benefit from your HPAC climate control module you should read through these
Installation and Maintenance Instructions.
HPAC combined with FIGHTER 1140/1240 is a climate control system for heating and cooling houses and
apartment buildings. Ground, rock or lakes can for instance be used as the heat exchange source.
HPAC is a Swedish-made quality product offering a long life span and reliable operation.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervi-
sion or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
Rights to make any design modifications are reserved.
20
To be filled in by the installation engineer when the heat
pump is installed
Installation date
Type designation/serial number
HPAC ____
Installation engineers
Type of brine _____________________
Mixing proportion/freezing point _______________
Settings
FIGHTER 1140/1240
Menu
9.2.16 Cooling system
2.3
Flow temp./MIN
2.9.1
Cooling curve
2.9.2
Offset cold curve
2.9.3
Starttemp. cooling
2.9.4
Diff Passive/Active
Date ______________
089 _ _ _ _ _ _ _ _ _ _ _
Factory
setting
Off
15
2
0
25
4
Signature_____________________