Fault Diagnosis - SICK GTE6-Serie Betriebsanleitung

Reflexions-lichttaster
Inhaltsverzeichnis
Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 7
5

Fault diagnosis

6
Table Fault diagnosis
8015312 | SICK
Subject to change without notice
5
+
L
L
D
D
Image: F
Sensor with potentiometer:
The sensitivity (sensing range) is adjusted with the potentiometer (type: 5-turn).
Clockwise rotation: sensitivity (sensing range) increased; counterclockwise rotation:
sensitivity (sensing range) reduced. We recommend placing the switching state in
the object, e. g., see graphic F. Once the sensitivity has been adjusted, the object is
removed from the path of the beam. The switching output changes (see graphic C).
The sensor is adjusted and ready for operation. Refer to graphics C and G to check
the function. If the switching output fails to behave in accordance with graphic C,
check application conditions. See section Fault diagnosis.
L
L
D
D
Q (PNP)
Q (NPN)
Q (NPN)
Q (PNP)
Image: C
Table indicates which measures are to be taken if the sensor stops working.
LED indicator/fault pattern /
LED indicator/fault pattern
Green LED does not light up /
Green LED does not light up
L
L
D
D
Cause /
Cause
No voltage or voltage below
the limit values /
No voltage or voltage below
the limit values
Measures /
Measures
Check the power supply,
check all electrical connecti‐
ons (cables and plug connecti‐
ons) /
Check the power supply,
check all electrical connecti‐
ons (cables and plug connecti‐
ons)
4
3
Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Gte6-pGte6-n

Inhaltsverzeichnis