Installation Instructions - Novy 1758 Montageanleitung Und Bedienungsanleitung

Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

INSTALLATION INSTRUCTIONS

The installation comes under the exclusive responsibility of specialists.
The installer is held to respect the legislation and the standards enforce in his home country.
How to stick the gasket:
The gasket supplied with the hob avoids all infiltration of liquids in the cabinet.
His installation has to be done carefully, in conformity of the following drawing.
Fitting - installing:
The cut out sizes are:
 Ensure that there is a distance of 50 mm between the hob and the wall or sides.
Cut size
Ref.
Width
1758
810 mm
 The hobs are classified as "Y" class for heat protection. Ideally the hob should be installed
with plenty of space on either side. There may be a wall at the rear and tall units or a wall
at one side. On the other side, however, no unit or divider must stand higher than
the hob.
 The piece of furniture or the support in which the hob has to be fit, as well as the edges of
furniture, the laminate coatings and the glue used to fix them, must be able to resist
temperatures of up to 100 °C.
 The mural rods of edge must be heat-resisting.
 Not to install the hob to the top of a not ventilated oven or a dishwasher.
 Guarantee a space of 20 mm under the bottom of the hob casing to ensure a good air
circulation of the electronic device.
 If a drawer is placed under the hob, avoid to put into this drawer flammable objects
(for example: sprays) or not heat-resistant objects.
 Materials often used to make worktops expand on contact with water. To protect the cut
out edge, apply a coat of varnish or special sealant. Particular care must be given to
applying the adhesive joint supplied with the hob to
prevent any leakage into the supporting furniture. This
gasket guaranties a correct seal when used in
conjunction with smooth work top surfaces.
 The distance between the hob and the cooker hood
placed above must respect the indications of the hood
manufacturer. In case of absence of instructions respect
a minimumdistance of 760 mm.
 The connection cord should be subjected, after building,
with no mechanical constraint, such for example of the
fact of the drawer.
Stick the gasket (2) two millimeters
from the external edge of the glass,
after removing the protection sheet (3).
Cut size flush mounting
Depth
Width
490 mm 886 mm 526 mm
63
Depth
Radius
Width
8 mm
880 mm
>76 mm
Glass size
Depth
Thickness
520 mm
4 mm
Inhaltsverzeichnis
loading

Inhaltsverzeichnis